    If you are looking for a bold, powerful roofing and cladding profile then LT7 should be your choice. Designed for applications where protection from severe climatic conditions and maximum structural economy is required, the strong section properties of LT7 allow for wider purlin and girt spacings which add extra economy to building projects. LT7 is particularly noted for its aesthetic appeal which was emphasised in its use on The Wellington Stadium as shown above. It also has excellent water shedding characteristics as well as being perfect for low pitch roofs.

    Cover: 889mm Sheet Width: 933mm
    Minimum Pitch 3° (approx 1:20)


    ROOFING SPAN CAPACITY CHART
    Thickness End Span Internal Span
    0.40mm 1.30m 1.80m
    0.55mm 2.00m 2.90m
    CLADDING SPAN CAPACITY CHART
    Thickness End Span Internal Span
    0.40mm 2.30m 3.00m
    0.55mm 3.00m 4.50m
    * To suit ultimate wind loads up to 3 kPa
    Note: Spans shown above are for steel. When using other materials please call 0800 Dimond for more info.

    All roofing spans shown are maximum spans to suit occasional foot traffic only. Not suitable for use as a platform for maintenance work.
    read more
    Go to technical specifications for this productGo to CAD & BIM files for this productGo to the contact details for this company
     
    CAD and BIM Content

    CAD & BIM Content (22)

    cad icon22 DWG
       right arrow icon Request additional CAD content

    Let us know the CAD & BIM file types that you require for this product.





    Name*
    Email*
    Notes
     
      
     
    Company Contact Details

    Contact Details

    Dimond

    48 Victioria Street

    Onehunga

    Auckland

    Select Theme